Function Of Input/Output Modules :

1. Control and Timing.
2. Processor Communication
3. Device Communication
4. Data Buffering.
5. Error Detection



Input/Output Module Structure

Data transferred to and from the module are buffered in one or more DATA REGISTERS.
STATUS REGISTER provide status information. They may also act as Control Register, to accept detailed control information from the processor.
The logic within the module interacts with the processor via a set of control lines. The processor uses the control lines to issue the commands to the I/O Modules. Some of the control lines may be used by the I/O Module (eg. for arbitration and status signals). The module must also be able to recognize and generate addresses associated with the devices it controls. Each I/O Module has a unique address or, if it controls more then one external device, a unique set of addresses.

An Input/Output Module that takes on most of the detailed processing burden, presenting a high-level interface to the processor, is usually referred to as an I/O CHANNEL or I/O PROCESSOR.

An I/O Module that is quite primitive and requires detailed control is usually referred to as an I/O CONTROLLER or DEVICE CONTROLLER.